beautypg.com

ADIC SNC 5100 User Manual

Page 159

background image

Commands

151

6-00020-02

SNC 5100

reboot

The

reboot

command requests that the SNC 5100 shut down existing

operations and then restart. This is the preferred method of restarting the SNC
5100. There are processes running within the SNC 5100 that may have writes
pending to files within the flash file system. Following a reboot command,
these processes flush their data to the flash file system, and the flash file system
writes all pending data out to the flash memory. Only after all pending data has
successfully been written to flash, will the SNC 5100 start a reset cycle.

SN60023 > reboot

reserveShow [level]

The

reserveShow

command outputs a list of devices with reservations.By

adding the flag “1” a list of all devices is output.

SN600393 > reserveShow

Idx Tdev

Vendor

Product

Rev

| Reservation ITL

Host's Port Name

----------------------------------------------|--------

value = 0 = 0x0

SN600393 > reserveShow 1

Idx Tdev

Vendor

Product

Rev

| Reservation ITL

Host's Port Name

----------------------------------------------|--------

0 0x8fda380 ADIC

SNC 5100

40b5 |

1 0x9ffcf08 IBM

DNES-309170W

SA30 |

value = 0 = 0x0

SN600393 >

reset

The

reset

command immediately initiates a reset cycle. Any pending data

Table 15: reserveShow Viewing Levels

Level

Explanation

Show target devices with reservations

1

Show all target devices regardless of whether a reservation is
held or not