writes to the flash file system will be lost. This operation is not typically used.
The

reboot

command should be used to gracefully shutdown and restart the

SNC 5100.

SN60023 > reset

restartScsi [channel]

The

restartScsi

command restarts the specified SCSI Channel without

issuing a bus reset.

SN60023 > restartScsi 1

value = 0 = 0x0

SN60023>

ridtag [

value

]

The

ridtag

command is used to change the replacement identifier (RID) tag

for the SNC 5100 after it has been replaced by the service representative. This
should be the final step after replacing and verifying that the replacement unit
is performing satisfactorily.

The

sysVpdShow

command will display the RID tag. Before replacing the

SNC 5100, you must determine the existing RID tag, if there is one, or the
original serial number if no replacement has been made.

If the

ridtag

command is entered with a string, that string becomes the RID

tag recorded for the unit.

SN60023 > ridtag “12D345677”

*** value = 0 = 0x0

If a string is not entered, the existing RID tag is displayed.

SN60023 > ridtag

RID Tag = 12D345677

value = 0 = 0x0

SN60023 >

On original equipment, the RID tag will be blank.