SNC 5100

180

Commands

6-00020-02

Device Index

10

IO Class Enum

n/a

IO Type Enum

n/a

Label Index

03

Bus Id

1.1.0

-------- SCSI 4 VPD --------

IO Class

Fixed IO

IO Type

SCSI

IO Mfg

LSI Logic

Device Index

11

IO Class Enum

n/a

IO Type Enum

n/a

Label Index

03

Bus Id

1.1.1

value = 0 = 0x0

buck172 >

sz

filename

The

sz

command initiates a send Zmodem file transfer session. You use this

command when you want to save configuration information to a file in case the
SNC 5100 needs to be replaced. The SNC 5100 uses Zmodem protocol to
upload its persistent address map database and configuration parameter
settings from its nonvolatile flash memory to a file on the service terminal.
After issuing this command, you start the file transfer from the service terminal
by initiating a receive file operation that uses Zmodem protocol.

The filename “config.cfg” is shown in the example below. You can specify a
different name for the file but the name must not exceed 8 characters and it
must end in .cfg. See also the

rz

command for information about receiving a

configuration file.

SN60023 > sz "config.cfg"

Configuration Download Complete: config.cfg

value = 0 = 0x0

SN60023 >

targets

The SNC 5100 maintains a list of target devices that are attached to the I/O
channels. The

targets

command will list each device currently attached,

providing descriptions of the devices.

SN60023 > targets