ADIC SNC 5100 User Manual
Page 188

SNC 5100
180
Commands
6-00020-02
Device Index
10
IO Class Enum
n/a
IO Type Enum
n/a
Label Index
03
Bus Id
1.1.0
-------- SCSI 4 VPD --------
IO Class
Fixed IO
IO Type
SCSI
IO Mfg
LSI Logic
Device Index
11
IO Class Enum
n/a
IO Type Enum
n/a
Label Index
03
Bus Id
1.1.1
value = 0 = 0x0
buck172 >
sz
“
filename
”
The
sz
command initiates a send Zmodem file transfer session. You use this
command when you want to save configuration information to a file in case the
SNC 5100 needs to be replaced. The SNC 5100 uses Zmodem protocol to
upload its persistent address map database and configuration parameter
settings from its nonvolatile flash memory to a file on the service terminal.
After issuing this command, you start the file transfer from the service terminal
by initiating a receive file operation that uses Zmodem protocol.
The filename “config.cfg” is shown in the example below. You can specify a
different name for the file but the name must not exceed 8 characters and it
must end in .cfg. See also the
rz
command for information about receiving a
configuration file.
SN60023 > sz "config.cfg"
Configuration Download Complete: config.cfg
value = 0 = 0x0
SN60023 >
targets
The SNC 5100 maintains a list of target devices that are attached to the I/O
channels. The
targets
command will list each device currently attached,
providing descriptions of the devices.
SN60023 > targets