Datesetfromrtc, Command on – ADIC SNC 5100 User Manual
Page 124
SNC 5100
116
Commands
6-00020-02
The local Real Time Clock can also be synchronized with a remote timeserver
See the
rtcSetCurrent
command.
SN60023 > date
SN60023 > THU JAN 25 20:32:49 2001
SN60023 >
dateSetFromRTC
The
dateSetFromRTC
command sets the SNC 5100’s RTC as the source of
the date display. Use the
date
command to display the date and time.
SN60023 > dateSetFromRTC
value = 0 = 0x0
SN60023 >
diagBoot
This command is used only to transition the SNC 5100 from normal operation
to the special diagnostic mode. The
diagBoot
command first ensures that the
ffs:mt directory exists. It verifies that the files diagnstk.o and diagnstk.rc are in
the flash file system. If they are in the root directory, it moves them to the ffs:mt
directory.
It copies the existing bootline to a file in the ffs:mt directory on the SNC 5100
and installs a new bootline directing the SNC 5100 to boot using a special
diagnostic startup script ffs:mt/diagnstk.rc. It renames the persistent map file
config/device.map as config/device.bak (a new file will be generated after
rebooting).
Finally,
diagBoot
issues a
reboot
command to put the changes into effect
Caution
After completing use of the diagnostic commands, use the
normalBoot
command to restore your system to normal operation.
diagHelp
The
diagHelp
command displays a list of the diagnostic commands.
SN60023 > diagHelp
** Diagnostic commands: Available in Diagnostic Mode Only **
elTest
Test Ethernet port w/loop-back cable
fcSlotTest