beautypg.com

ADIC SNC 5100 User Manual

Page 44

background image

SNC 5100

36

Event Codes and Actions

6-00020-02

N.A.

N.A.

N.A.

Persistent reboots

3

N.A.

N.A.

N.A.

Host application error message or host
log entry indicates SCSI target error

12

N.A.

N.A.

N.A.

Host cannot access attached devices

12

N.A.

N.A.

N.A.

SAN Connection LED off although
cables are attached and host systems
are on and have booted

2

N.A.

N.A.

N.A.

Heartbeat failure

7

N.A.

N.A.

N.A.

fcShow

command returns

Firmware State = Sync

Lost

2, 0

N.A.

N.A.

N.A.

ADIC Management Console failure

7

N.A.

N.A.

N.A.

Service terminal connection failure

8

Generic Event Descriptions

8

2

0

Sense data recorded following a check
condition
Caution: Normally, the host system
will request and process send data and
then perform error recovery

0

9

1

0

LUN reports a “unit attention”
condition on a non-removable media
device

0

11

1

1

ADIC Management Console reports a
temperature change (event message
indicates the change to High, Very
High, Reduced, to High, or OK

4

13

1

1

SNC 5100 is shutting down as
requested by the ADIC Management
Console
(a Restart was requested)

0

14

0

0

Additional status information used for
diagnostics

0

Table 7: Event Codes and Actions

Event

Code

Viewing

Level

1

Default

Trap

Threshold

Description

Action

2