ADIC SNC 5100 User Manual

Page 134

background image

SNC 5100

126

Commands

6-00020-02

fcPortModeSet [port],[mode]

The

fcPortModeSet

command sets the mode for the specified Fibre Channel

port. See also the

fcPortModeGet

command.

The default port mode is Public Target. Consequently, if attached to a Fabric
device the SNC 5100 will register as a Target with the name server. If the port
mode is Private Target, the SNC 5100 does not register with the name server
and the Fabric device will not recognize the SNC 5100 as a Target.

The port must be in Initiator mode if you want the SNC 5100 to scan for target
devices on the port. When the port is in Private Initiator mode, the SNC 5100
only scans for devices on the local loop. If the port mode is in Public Initiator
mode, the SNC 5100 also scans for devices attached to a Fabric.

SN60023 > fcPortModeSet 1,2

value = 0 = 0x0

SN60023 >

Caution

You must issue the

fcRestart

command or reboot the SNC 5100

for the new setting to take effect. See the

fcRestart

command for

further information.

fcRestart [port]

The

fcRestart

command restarts the specified Fibre Channel port. You

Parameter

Value

Meaning

Port

1

The SNC 5100 connection labeled FC1

2

The SNC 5100 connection labeled FC2

Mode

1

Private Target

2

Private Initiator

3

Private Target and Initiator

17

Public Target

18

Public Initiator

19

Public Target and Initiator