beautypg.com

ADIC SNC 5100 User Manual

Page 125

background image

Commands

117

6-00020-02

SNC 5100

w/loop-back cable

normalBoot

Shutdown and restart in normal mode

scsiChannelTest Test specified SCSI Channels w/loop-back

cable

See User’s Guide for more information

value = 0 = 0x0

SN60023 >

disableCC [option number]

Disable the command and control interface (LUN 0) using the

disableCC

command. Specify one of two option parameters as follows.

The SNC 5100 is addressable as a SCSI target device for command and control
support. On a Fibre Channel Interface, this device will be seen as logical unit
number 0, (LUN 0). The LUN 0 device returns a device type of 0Ch in an
inquiry command, indicating it is a controller device. Controller devices are
defined in the SCSI-3 Controller Commands specification (SCC).

In some cases, it may be desirable to disable this feature. If LUN 0 is disabled,
then a device type of 2Ch will be returned in an inquiry to LUN 0, indicating
that the device is not presently available at this LUN. LUN 0 will remain
reserved for the Command and Control interface and will not be allocated to
another target device.

Other commands are available for re-enabling the Command and Control
interface or reassigning it to a different LUN rather than hiding or disabling it.
See the

enableCC

command and the

setSnaCCLun

command for further

information.

Caution

If you enter the

disableCC

command without specifying an option

number, it has the same effect as

disableCC 1

SN60023 > disableCC

value = 0 = 0x0

SN60023 >

Option

Number

Value

1

Hides the Command and Control interface and results in Inquiry data
returning “device not available” for LUN 0.

2