beautypg.com

ADIC SNC 5100 User Manual

Page 101

background image

Post-Repair Checklist

93

6-00020-02

SNC 5100

10

From the service
terminal, enter the

fcShow

command to

show the status of each
FC interface that is
installed and connected.

From the service
terminal, enter the

fcShowDevs

command to show the
SCSI target devices that
are connected as seen by
the Fibre Channel
interface.

In the output of the

fcShow

command, look for the

Firmware State column.

If the word Ready does not appear, go to “Fibre
Channel MAP” on page 61.

Check to see that all SCSI target devices are seen by
each FC interface.

If not, go to “SCSI Channel MAP” on page 50.

11

Verify that all (or the
designated) target
devices are available to
the host systems.

Use appropriate host system utilities for tape.
See Table 4, “Host Utility Software,” on page 23.

If “Access Control” is enabled (Channel Zoning or
SFM) the hosts will only see the devices that have
been assigned to them.

If the designated devices are NOT available, reboot
the host and check again.

If the problem persists, go to “Start MAP” on page 42.

12

Disconnect the RS-232
cable from the and from
the service terminal.

None.

13

End of repair.

Table 4-1: Post-Repair Checklist

Step

Actions

Comments and References