Check fibre channel port status, Check scsi channel devices – ADIC SNC 5100 User Manual
Page 57
Device Access MAP
49
6-00020-02
SNC 5100
For information about how to do this, see “Connecting to the
Service Port” on page 95.
Step 2.
Press the Enter key on the service terminal.
If the prompt is not displayed, go to “Service Port MAP” on
page 75.
Check Fibre Channel Port Status
Step 1.
Enter the
fcShow
command from the service terminal.
For more information, see the
If the
fcShow
command does not display a Firmware State of
Ready for the attached Fibre Channel SAN connections, go to
“Fibre Channel MAP” on page 61.
Step 2.
If a Fibre Channel host should have access to SCSI Channel
devices, verify that the FC port mode is Target.
The SNC 5100 Fibre Channel ports are set by default to Target
mode. If the port mode for the host connection was changed to
Initiator, the host will not be able to see the SCSI devices.
For more information on setting Channel modes, see the ADIC
Management Console User Guide.
Step 3.
If the host should have access to devices on a Fibre Channel, verify
that the FC port mode is set to Initiator or Target and Initiator.
If the port mode for the host connection is set to Target, the host
will not be able to see the attached Fibre Channel devices.
For more information on setting Channel modes, see the ADIC
Management Console User Guide.
Check SCSI Channel Devices
Enter the
scsiShow
command from the service terminal.
For more information, see the