beautypg.com

Check fibre channel port status, Check scsi channel devices – ADIC SNC 5100 User Manual

Page 57

background image

Device Access MAP

49

6-00020-02

SNC 5100

For information about how to do this, see “Connecting to the
Service Port” on page 95.

Step 2.

Press the Enter key on the service terminal.

If the prompt is not displayed, go to “Service Port MAP” on
page 75.

Check Fibre Channel Port Status

Step 1.

Enter the

fcShow

command from the service terminal.

For more information, see the

"fcShow [level]"

command on

page 127.

If the

fcShow

command does not display a Firmware State of

Ready for the attached Fibre Channel SAN connections, go to
“Fibre Channel MAP” on page 61.

Step 2.

If a Fibre Channel host should have access to SCSI Channel
devices, verify that the FC port mode is Target.

The SNC 5100 Fibre Channel ports are set by default to Target
mode. If the port mode for the host connection was changed to
Initiator, the host will not be able to see the SCSI devices.

For more information on setting Channel modes, see the ADIC
Management Console User Guide
.

Step 3.

If the host should have access to devices on a Fibre Channel, verify
that the FC port mode is set to Initiator or Target and Initiator.

If the port mode for the host connection is set to Target, the host
will not be able to see the attached Fibre Channel devices.

For more information on setting Channel modes, see the ADIC
Management Console User Guide
.

Check SCSI Channel Devices

Enter the

scsiShow

command from the service terminal.

For more information, see the

"scsiShow"

command on page 160.