ADIC SNC 5100 User Manual
Page 47

Event Codes and Actions
39
6-00020-02
SNC 5100
61
4
1
1
Inlet Air, Outlet Air, or I/O Processor
temperatures have entered Nominal
Range from a Warning or Alarm
Range
0
62
4
1
1
Inlet Air Temperature has entered
Warning Range from Nominal Range
(heating up) or Alarm Range (cooling
down)
4
63
1
1
Inlet Air Temperature has entered
Alarm Range
4
64
4
1
1
Outlet Air Temperature or I/O
Processor Temperature has entered
Warning Range from Nominal or
Alarm Ranges
4
65
1
1
Outlet Air Temperature or I/O
Processor Temperature has entered
Alarm Range
4
66
1
1
Fan is operating in Nominal Range
after operating in a fault state
0
67
1
1
Fan speed has entered Warning Range
(Tachometer fans only)
4
68
1
1
Fan speed has entered Alarm Range
(Tachometer fans) or is stalled (rotor
stall fans)
4
70
5
1
1
Firmware upload completed
0
71
5
1
1
SNC 5100 restart completed
0
72
1
1
Maximum number of initiators has
been exceeded
0
150
1
1
The event log is about to overwrite
the earliest events
0
Health Check Event Descriptions
100
1
1
Power supply is out of specification
5
Table 7: Event Codes and Actions
Event
Code
Viewing
Level
1
Default
Trap
Threshold
Description
Action
2