10 errors, 11 restrictions in the offline mode – GW Instek APS-1102 Control Software User Manual User Manual
Page 36

APS-1102 Control Software User Manual
4-12
4.10 Errors
“RMT” checks for device errors when the device has been set in the online status.
If an error occurs on the device, an error message appears.
Figure 4-15 Error Message Example
The error message displays the error number and details for the corresponding error. For details,
see the device manual.
If an error occurs after a certain item is set to the device, the device is querried for the setting
item value and the result is reflected on the remote control screen.
4.11 Restrictions in the Offline Mode
If the mode or range is switched in “RMT” in the online status, all parameters are querried after
completion of switching operation and the results are reflected on the remote control screen.
The following restrictions apply in the offline status because the device status is not imitated.
a) Mode switching
After the mode switching operation, each setting item displays the setting value or details that
were set immediately before the operation.
b) Range switching
The value of the item for which setting range varies depending on the range after range
switching operation is rounded to the allowable maximum value.
c) Creation of device setting file
To create the device setting file in the offline status, be sure to set each setting item before
clicking the corresponding SET button.