beautypg.com

GW Instek APS-1102 Control Software User Manual User Manual

Page 119

background image

11.4 Transfer Arbitrary Wave Data

11-5

<4> Transfer

When the Transfer button is clicked, the arbitrary wave data will be transferred to the
device.

<5> Cancel

When the Cancel button is clicked, the operation is cancelled and the [Transfar arbitrary
wave data]
dialog box closes.

The following types of arbitrary waveform files can be read:

 Plain text file (extension: “.txt”)

Range of data:

16384 to 16383

Contents of file: One data entry (no comma, left-justified) per line

16384

1000
2

10

 Text file that was output with “ARB Arbitrary Waveform Editor”
(extension:

“.txt”)

 2’s complement binary files (extension: “.arb”)

Range of data:

16384 to 16383

Contents of file: 4,096 words must be saved with big endian

0, 1000, 1500, 2000, … , -3000

In the above example, the data is organized in the following order from
the top of the file.

0x00, 0x00, 0x03, 0xE8, 0x07, 0xd0, …, 0xF4, 0x48

 Binary file that was output with ARB Arbitrary Waveform Editor
(extension:

“.wdb”)


The arbitrary waveform size of the APS-1102 Programmable AC/DC Power Source is 4,096 words
(1 word = 16 bits).

The number of arbitrary waveform data units within an arbitrary waveform file must always be
4,096 words. If it is insufficient, an error message will appear.


4,096 lines are required.

Caution