beautypg.com

GW Instek APS-1102 Control Software User Manual User Manual

Page 103

background image

9.6 Sequence Control Buttons

9-13

<4> [Stop] button

This button is used to stop the sequence. The output when the sequence is stopped is held.
After this button has been pressed, the Stop, Hold, and Branch button will be unavailable.
Clicking the Start button in this state can restart the sequence, beginning at step 1.

<5> [Hold] button

This button is used to stop the sequence temporarily. The output when the sequence is paused
is held.
Clicking the Start button can resume the sequence from a step that has temporally stopped.
Click the Stop button to terminate the sequence.

<6> [Branch] button

This button is used to branch the sequence. Clicking the Branch button with a branch
channel number entered into the [Branch Channel] field moves the sequence to the step
currently set in the branch step.