beautypg.com

Auto collect – Spectra Precision Survey Pro v3.80 Recon iPAQ Reference Manual User Manual

Page 98

background image

Survey Pro Reference Manual

R-92

Auto Collect

6XUYH\ $XWR &ROOHFW

The Auto Collect screen allows users with robotic total stations to
automatically collect points either at a specified time interval or after
the rod has moved a specified horizontal distance.

Note: This routine only works when used with a robotic total station
in remote control mode.

6HWWLQJV : located at the top of the screen, is a shortcut

to the Surveying Settings screen (Page R-34).

Foresight

: is the point name that will be used when

storing the first new point. Each successive point name
will automatically be incremented by the next available
point number.

Description

: is the description that will be assigned to all

the points that are stored from this routine.

Time

: when this radio button is selected, a point will

automatically be stored after each time specified in the
corresponding field passes.

Distance

: when this radio button is selected, a point

will automatically be stored each time the prism is
moved from the last stored point by the horizontal
distance specified in the corresponding field.

Note: The accuracy that a point will be stored when auto collecting
by Distance will vary depending on how frequently the total station
measures a distance and how fast the prism is traveling.

%DFNVLJKW« : accesses the Backsight Setup screen (Page R-78).

1H[W ! : accesses the next screen.