R-86

Repetition Shots

6XUYH\ 5HSHWLWLRQ 6KRWV

The Repetition Shots screen is used to perform side shots or traverse
shots using any number of repetitions.

Note: The sequence that the repetition shots are performed is
selected in the Repetition Settings screen (Page R-38).

6HWWLQJV : located at the top of the screen, is a shortcut

to the Surveying and Repetition Settings screens (Page
R-34 and R-38 respectively).

Foresight

: is the name of the point that will be stored.

Number of Sets

: is the desired number of sets to shoot to

the backsight and foresight.

Note: One set is equivalent to two shots to the backsight
and foresight point.

HR

: is the rod height.

Average (of)

: shows the average angle or distance to the

foresight from all the shots taken. The value in
parenthesis is the total number of repetitions performed.

Worst Residual

: displays the worst residual calculated from all the

sets of the selected measurement type.

Description

: is the description for the point that is being stored. This

field appears prior to storing the new point.

Note: A residual is the difference between a single measurement and
the average of all the measurements.