beautypg.com

Results – Spectra Precision Survey Pro v3.80 Recon iPAQ Reference Manual User Manual

Page 186

background image

Survey Pro Reference Manual

R-180

Note: a boundary has two fixed sides and one side defined by a
direction when using the Hinge Method. It has one fixed side and two
sides defined by a direction when using the Parallel Method.

(GLWRU« : accesses the Polyline Editor (Page R-48) where

a new polyline can be created or an existing polyline can
be modified.

7DS 3RLQWV« : provides a map view where you can tap

any existing points to define the fixed sides of the
boundary.

7R)URP« : provides point selection by entering point

names.

;

Store Pt 1

/

2

: When checked, will store a point at the

location of the end point(s) of the computed boundary
line.

$]LPXWK / %HDULQJ : defines the direction of the

boundary sides with lengths that are not yet known.

Results

Point 1

/

2

: Displays the coordinate of the end points of the computed

boundary line.

Total Area

: is the total area of the boundary.

Plot Area

: is the area enclosed by the pre-defined fixed boundary

lines.

Difference

: is the difference between the

Total Area

and the

Plot Area

.