Shots – Spectra Precision Survey Pro v3.80 Recon iPAQ Reference Manual User Manual
Page 112
Survey Pro Reference Manual
R-106
Shots
Number of sets
: is the number of sets that will be taken
to the celestial object.
Reverse Shots
;: When checked, reverse shots will be
required with each set. When unchecked, only direct
shots are required.
6KRRW : accesses the Enter Shot Data screen, described
below, where the shot data is entered for the selected
observation.
7RVV / ,QFO : will toggle the selected observation so that
it will be hidden or un-hidden, respectively. When an
observation is hidden, it will not be used when
calculating the final azimuth.
Note: The
7RVV / ,QFO buttons perform the same function as
checking / un-checking the checkbox in front of each observation.
Note: A backsight observation cannot be tossed.
'HO : permanently deletes the most current observation if it is
selected allowing you to shoot that shot again.
5HVHW : permanently deletes all observations. A warning prompt will
appear before the observations are deleted.