Adjust Menu
R-241
Traverse Adjust – Results
This screen displays the changes that will be made by the
adjustment, where they can be previewed before the actual
adjustment is made.
The screen lists the adjustment details in three main sections:
the angle adjustment details; the compass rule adjustment
details, and the point details where the before-and-after
coordinates for each point are listed. An example of the
information provided in the Preview screen is shown here.
Error dist
: is the horizontal distance between the starting point
and closing point.
Error azm
: is the direction from the closing point to the starting
point.
Precision
: is the ratio of the error distance to the length.
Angular error
: is the difference between (N
-
2)·180 and the actual
sum of the internal angles, where N is the number of sides in the
traverse.
Length
: is the sum of all the sides of the boundary.
Perimeter
: is the length plus the error distance.
$GMXVW : if the results in the preview are acceptable tap this