App index, Basic setting commands – Yokogawa Value Series FX1000 User Manual
Page 89
3-7
IM 04L21B01-17EN
Commands
1
2
3
4
5
6
App
Index
Basic Setting Commands
• To apply settings that you have changed using the basic setting commands, you need
to save the settings using the YE or XE command. Be sure to save the settings before
you change the execution mode from the basic setting mode to the operation mode.
Otherwise, the new settings will not be applied.
• The settings that are returned in response to a query in basic setting mode contain
the new settings even if they have not been saved. However, the new settings are
not applied unless they are saved. If the settings are cleared or if you change the
execution mode from basic setting mode to operation mode before saving the settings,
the settings that are returned in the response to a query contain the settings that were
in use before they were changed.
Note
• The settings that are changed using the
YA, YK, RU, YQ, YS, YB, YD, WS, WW, and WQ
commands are applied after saving the new settings using the
XE command and restarting
the FX.
• When you execute the
YE or YO command, communication is disconnected. Commands
listed after the YO or YE command are ignored.
Command
Name
Function
Execution Mode Administrator User Page
WU
Sets the environment
Basic setting mode Yes
No
3-34
WO
Sets alarm and DO settings
Basic setting mode Yes
No
3-36
WH
Sets alarm hysteresis
Basic setting mode Yes
No
3-36
XV
Sets the scan interval and A/D integration time
Basic setting mode Yes
No
3-37
XB
Sets burnout detection
Basic setting mode Yes
No
3-37
XJ
Sets RJC
Basic setting mode Yes
No
3-37
XM
Sets the memory sampling condition
Basic setting mode Yes
No
3-37
RF
Sets the key lock
Basic setting mode Yes
No
3-37
RN
Sets basic login
Basic setting mode Yes
No
3-38
RP
Sets user limitations
Basic setting mode Yes
No
3-38
RO
Sets the type of report and when to create reports (/M1, /PM1, and
/PWR1 options)
Basic setting mode Yes
No
3-38
RM
Sets a report channel (/M1, /PM1, and /PWR1 options)
Basic setting mode Yes
No
3-39
XG
Sets the time zone
Basic setting mode Yes
No
3-39
XN
Sets the date format
Basic setting mode Yes
No
3-39
YB
Sets host information (/C7 option)
Basic setting mode Yes
No
3-39
YD
Sets network parameters (/C7 option)
Basic setting mode Yes
No
3-40
YA
Sets the IP address, subnet mask, and default gateway (/C7 option) Basic setting mode Yes
No
3-40
YK
Sets keepalive (/C7 option)
Basic setting mode Yes
No
3-40
RU
Sets DNS parameters (/C7 option)
Basic setting mode Yes
No
3-40
WS
Sets a server (/C7 option)
Basic setting mode Yes
No
3-40
WW
Sets web page parameters (/C7 option)
Basic setting mode Yes
No
3-40
YQ
Sets the communication timeout (/C7 option)
Basic setting mode Yes
No
3-41
YT
Sets the FTP transfer timing (/C7 option)
Basic setting mode Yes
No
3-41
YU
Sets what kind of information to send using e-mail (/C7 option)
Basic setting mode Yes
No
3-41
YV
Sets an e-mail recipient address (/C7 option)
Basic setting mode Yes
No
3-42
YW
Sets the e-mail sender address (/C7 option)
Basic setting mode Yes
No
3-42
YX
Sets the e-mail SMTP server name (/C7 option)
Basic setting mode Yes
No
3-42
YJ
Sets the Modbus client’s destination server (/C7 option)
Basic setting mode Yes
No
3-42
YP
Sets basic Modbus client settings (/C7 option)
Basic setting mode Yes
No
3-43
YR
Sets the Modbus client’s transmit command (/C7 option)
Basic setting mode Yes
No
3-43
WB
Sets SNTP client parameters (/C7 option)
Basic setting mode Yes
No
3-43
WC
Sets the SNTP operation that is performed when memory start is
executed (/C7 option)
Basic setting mode Yes
No
3-44
YS
Sets the serial interface (/C2 and /C3 options)
Basic setting mode Yes
No
3-44
YL
Sets the operation of the Modbus master function (/C2 and /C3
options)
Basic setting mode Yes
No
3-44
3.2 List of Commands