Yokogawa Value Series FX1000 User Manual
Page 110
3-28
IM 04L21B01-17EN
When p2 is set to
INFORMATION, select
from the items below
ALARM
Alarm summary
MESSAGE
Message summary
MEMORY
Memory summary
MODBUS_CLIENT Modbus TCP status
display
MODBUS_MASTER Modbus RTU status
display
RELAY
Relay status display
REPORT
Report display
TO_HISTORY
To the historical
display
TO_HISTORY_D
To historical (display
data)
TO_HISTORY_E
To historical (event
data)
TO_OVERVIEW
To the overview display
SORT_KEY
Sort key switching
SORT_ORDER
Sort order switching
DISP_ITEM
Date/user name
switching
DATA_KIND
Data type switching
DATE/FILE
Date/file name
switching
SELECT_SAVE
Select save
REPORT_CHANNEL Report channel
display switching
ALL_SAVE
Save all
MANUAL_SAVE
Save manual samples
REPORT_SAVE
Save reports
DATA_SAVE_MODE Data save mode
COLUMN_BAR
Stacked bar graph
COLUMN_BAR_DISP Single graph or dual
graph
COLUMN_BAR_SELECT
Selects bar or group
REPORT_GROUP1 to REPORT_GROUP4
Selects the report
group
DISP_GROUP
Group number display
SEPARATOR
When p2 is set to
LOG, select from the items
below
LOGIN_LOG
Login log
ERROR_LOG
Error log
COMMU_LOG
Communication log
FTP_LOG
FTP log
WEB_LOG
Web log
MAIL_LOG
E-mail log
SNTP_LOG
SNTP log
DHCP_LOG
DHCP log
MODBUS_LOG
Modbus log
SEPARATOR
Example Display the following items in the following order
on the Trend main menu’s sub menu: SCALE
and DIGITAL.
SMDISP_SUB,TREND,SCALE,DIGITAL
Description • The items that you can set for p3 and the
subsequent parameters vary depending on
p2.
• If you omit parameter p3 and the subsequent
parameters, all menu items are hidden.
• If you specify the same menu item multiple
times, a command error will occur.
• You can specify up to three separators. If you
specify any more, an error will occur.
• You cannot use delimiters to omit parameters
(, ,).
• The SMDISP_SUB? command causes the
FX to also return sub menu items that are not
being displayed.
• If you specify “SEPARATOR” as the first menu
item, it will be ignored.
• The display on/off setting of the display group
parameters “GROUP1” to “GROUP10” and the
auto switching parameter “AUTO” apply to the
trend, digital, bar graph, and historical trend
menus. (For example, if you set AUTO to off
for the trend menu, and then set AUTO to on
for the digital menu, AUTO will be turned on
for the trend, digital, bar graph, and historical
trend menus.)
• You cannot specify DATA_SAVE_MODE,
SELECT_SAVE, REPORT_SAVE, ALL_SAVE,
and MANUAL_SAVE on models that do not
have a CF card slot or USB interface (/USB1
option).
• You cannot specify MODBUS_CLIENT,
FTP_LOG, MAIL_LOG, WEB_LOG,
SNTP_LOG, and DHCP_LOG on models that
do not have an Ethernet interface (/C7 option).
• You cannot specify MODBUS_MASTER on
models that do not have a serial interface (/C2
or /C3 option).
• You cannot specify COMMU_LOG and
MODBUS_LOG on models that do not have
a communication interface (/C2, /C3, or /C7
option).
• You cannot specify REPORT,
REPORT_CHANNEL, REPORT_SAVE,
COLUMN_BAR, COLUMN_BAR_DISP,
COLUMN_BAR_SELECT, or
REPORT_GROUP on models that do not
have the /M1, /PM1, or /PWR1 math option.
3.4 Setting Commands