2 serial interface specifications, 2 serial interface specifications -2, Rs-232 specifications – Yokogawa Value Series FX1000 User Manual
Page 176
6-2
IM 04L21B01-17EN
6.2 Serial Interface Specifications
RS-232 Specifications
Connector type:
D-Sub 9-pin plug
Electrical and mechanical specifications:
Conforms to the EIA-574 standard (for the 9-pin interface of the
EIA-232 (RS-232) standard)
Connection:
Point-to-point
Transmission mode:
Half-duplex
Synchronization:
Start-stop synchronization
Baud rate:
Select from 1200, 2400, 4800, 9600, 19200, and 38400 [bps].
Start bit:
1 bit (fixed)
Data length:
Select 7 or 8 bits (To output data in BINARY format, be sure to
set the data length to 8 bits.)
Parity:
Select odd, even, or none
Stop bit:
1 bit (fixed)
Hardware handshaking: Select whether to fix the RS and CS signals to TRUE or to use
the signal for flow control.
Software handshaking: Select whether to use the X-ON and X-OFF signals to control
the transmitted data only or both the transmitted and received
data.
X-ON (ASCII 11H), X-OFF (ASCII 13H)
Received buffer size:
2047 bytes
RS-422A/485 Specifications
Terminal block type:
6 point, terminal block, terminal screws: M3/nominal length
6 mm
Electrical and mechanical specifications:
Conforms to the EIA-422 (RS-422A) and EIA-485 (RS-485)
standards
Connection:
Multidrop
Four-wire type
1:32
Two-wire type
1:31
Transmission mode:
Half-duplex
Synchronization:
Start-stop synchronization
Baud rate:
Select from 1200, 2400, 4800, 9600, 19200, and 38400 [bps].
Start bit:
1 bit (fixed)
Data length:
Select 7 or 8 bits
Parity:
Select odd, even, or none
Stop bit:
1 bit (fixed)
Received buffer size:
2047 bytes
Escape sequence:
Open and close
Electrical characteristics: FG, SG, SDB, SDA, RDB, and RDA (six points)
SG, SDB, SDA, RDB, and RDA terminals and the internal
circuit of the FX is functionally isolated.
FG terminal is the frame ground.
Communication distance: Up to 1.2 km
Terminator:
External: recommended resistance 120 Ω, 1/2 W