beautypg.com

App index – Yokogawa Value Series FX1000 User Manual

Page 87

background image

3-5

IM 04L21B01-17EN

Commands

1

2

3

4

5

6

App

Index

Command

Name

Function

Execution Mode Administrator User Page

TQ

Sets a timer

Operation mode Yes

No

3-22

TK

Sets a match time timer

Operation mode Yes

No

3-22

TU

Sets an event action

Operation mode Yes

No

3-23

SK

Sets a computation constant (/M1, /PM1, and /PWR1 options)

Operation mode Yes

No

3-24

SI

Sets the rolling average function of a computation channel (/M1,

/PM1, and /PWR1 options)

Operation mode Yes

No

3-24

SJ

Sets a TLOG timer (/M1, /PM1, and /PWR1 options)

Operation mode Yes

No

3-24

TX

Sets the ancillary operation of the start key (/M1, /PM1, and /PWR1

options)

Operation mode Yes

No

3-25

BH

Sets a batch text field

Operation mode Yes

No

3-25

EH

Sets calibration correction (/CC1 option)

Operation mode Yes

No

3-25

BD

Sets an alarm delay

Operation mode Yes

No

3-25

NP

Sets the VT ratio, CT ratio, and low-cut power (/PWR1 option)

Operation mode Yes

No

3-25

FR

Sets the interval for acquiring data to the FIFO buffer

Operation mode Yes

No

3-26

SM

Sets the custom menu

Operation mode Yes

No

3-27

3.2 List of Commands