beautypg.com

Manual sampled/report data size, User information – Yokogawa Value Series FX1000 User Manual

Page 164

background image

4-28

IM 04L21B01-17EN

Manual Sampled/Report Data Size

This is generated by the MO command.

• Syntax

EACRLF
zzz···CRLF
ENCRLF

zzz···The data size (10 digits max.)

• Example

EACRLF
12345
ENCRLF

User Information

• The FU command is used to output the data.
• User name, user level, and other information are output.

• Syntax

EACRLF
p_l_uuu···CRLF
ENCRLF

p Login method

E: Ethernet
S: RS-232 or RS-422A/485
K: Login using keys

l User level

A: Administrator
U: User

uuu··· User name (up to 20 characters)
_ Space

• Example 1

When the

FU0 command is used, only the information of the logged in user is output.

EA
E A admin
EN

• Example 2

When the

FU1 command is used, information on all users logged in through a general-

purpose service or using keys is output.
EA
K A admin_abc
E A admin_def
E U user0033
E U user0452
EN

4.2 Output Format of Text Data