YQ

Sets the communication timeout

(/C7 option)

When you are not using a timeout

Syntax

YQ p1
p1 Communication timeout (OFF)

Query

YQ?

Example Disable the communication timeout.

YQOFF

When you are using a timeout

Syntax

YQ p1,p2
p1 Communication timeout (ON)
p2 Timeout value in minutes (1 to 120)

Query

YQ?

Example Enable the communication timeout, and set the

timeout value to 3 minutes.
YQON,3

YT

Sets the FTP transfer timing (/C7

option)

Syntax

YT p1,p2,p3
p1 Automatically transfer data when display

data files and event data files are created
(ON, OFF)

p2 Automatically transfer data when report data

files are created (ON, OFF)

p3 Automatically transfer data when snapshot

data files are created—when a snapshot is
executed (ON, OFF)

Query

YT?

Example Set the FX to automatically transfer display data

files and event data files. Do not transfer report
data files or screen image data files.
YTON,OFF,OFF

Description • When the method to save data to the external

storage medium is set to “Auto,” the FX
automatically transfers data files when they
are created. For the setting procedure for the
method to save data to the external storage
medium, see the FX1000 User’s Manual, IM
04L21B01-01EN.

• Parameter p2 is only valid on models with the

/M1, /PM1, or /PWR1 math option.

YU

Sets what kind of information to

send using e-mail (/C7 option)

When you want to send changes in the status of

alarms

Syntax

YU p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,
p11,p12
p1 Information to send (ALARM)
p2 Recipient 1 (ON, OFF)
p3 Recipient 2 (ON, OFF)
p4 Transmission of the alarm number 1 status (ON,

OFF)

p5 Transmission of the alarm number 2 status (ON,

OFF)

p6 Transmission of the alarm number 3 status (ON,

OFF)

p7 Transmission of the alarm number 4 status (ON,

OFF)

p8 Inclusion of instantaneous data (ON, OFF)
p9 Inclusion of the source URL (ON, OFF)
p10 Subject (up to 32 characters)
p11 Header 1(up to 64 characters)
p12 Header 2(up to 64 characters)

Query

YU[p1]?

Example Send the status of alarm numbers 1 to 4 to

recipient 1. Include instantaneous data but
not the source URL. Set the subject to “ALM,”
header 1 to “LP2,” and header 2 to “FX.”
YUALARM,ON,OFF,ON,ON,ON,ON,ON,OFF,
ALM,LP2,FX

When you want to send e-mail at scheduled times

Syntax

YU p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,
p11,p12
p1 Information to send (TIME)
p2 Recipient 1 (ON, OFF)
p3 Interval for sending e-mail to recipient 1

(1H, 2H, 3H, 4H, 6H, 8H, 12H, 24H)

p4 Time to send e-mail to recipient 1 (00:00 to

23:59)

p5 Recipient 2 (ON, OFF)
p6 Interval for sending e-mail to recipient 2

(1H, 2H, 3H, 4H, 6H, 8H, 12H, 24H)

p7 Time to send e-mail to recipient 2 (00:00 to

23:59)

p8 Inclusion of instantaneous data (ON, OFF)
p9 Inclusion of the source URL (ON, OFF)
p10 Subject (up to 32 characters)
p11 Header 1(up to 64 characters)
p12 Header 2(up to 64 characters)

Query

YU[p1]?

Example Send an e-mail to recipient 1 every day at 17:15.

Do not include instantaneous data, but include
the source URL. Set the subject to “GOOD” and
header 1 to “LP2.”
YUTIME,ON,24H,17:15,OFF,,,OFF,ON,
GOOD,LP2

3.6 Basic Setting Commands