beautypg.com

10 output commands (special response commands), Through ethernet communications) -52 – Yokogawa Value Series FX1000 User Manual

Page 134

background image

3-52

IM 04L21B01-17EN

3.10 Output Commands (Special

response commands)

*I

Outputs instrument information

Syntax

*I

Description Upon receiving this command, the FX outputs

the following information about itself as a
comma-separated string of ASCII characters with
a terminator at the end: manufacturer, model,
serial number, and firmware version.

Output example

YOKOGAWA,FX1000,99AA0123,F1.01

3.11 Maintenance/Test

Commands (Available when

using the maintenance/test

server function through

Ethernet communications)

close Closes another device’s

connection

Syntax

close,p1,p2:p3
p1 Port on the FX (1 to 65535)
p2 PC IP address

(0.0.0.0 to 255.255.255.255)

p3 Port on the PC (0 to 65535)

Example close,34159,192.168.111.24:1054

E0

Description You cannot use this command to disconnect a

server port. You also cannot use this command
to disconnect from the instrument that you are
operating. Use the quit command instead.

con

Outputs connection information

Syntax

con

Example

con
EA
11/06/09 12:34:56

Active connections

Proto Local Address Foreign Address State
TCP 192.168.111. 24:34261 192.168.111. 24:1053 ESTABLISHED
TCP 0. 0. 0. 0:80 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34261 0. 0. 0. 0:

0 LISTEN

TCP 0. 0. 0. 0:34260 0. 0. 0. 0:

0 LISTEN

EN

TCP
Protocol used
Local Address
FX socket address
Displays “IP address:port number”
Foreign Address
Destination socket address
Displays “IP address:port number”
State
Connection state
ESTABLISHED
Connection established

3.10 Output Commands (Special response commands)/3.11 Maintenance/Test Commands