App index – Yokogawa Value Series FX1000 User Manual
Page 117
3-35
IM 04L21B01-17EN
Commands
1
2
3
4
5
6
App
Index
Computation settings
Syntax
WU p1,p2,p3,p4
p1 Setting type (MATH)
p2 Display on error
+OVER Positive overflow
-OVER Negative overflow
p3 Data when the SUM or AVE value overflows
ERROR Sets the computed result to the
value of the computation error
SKIP
Discards the data that overflowed
and continues the computation
LIMIT Processes the data as follows:
• For measurement channels
that do not have linear scaling
specified, the FX sets the data
to the upper or lower limit of the
measuring range.
• For measurement channels that
have linear scaling specified,
the FX sets the data to the
specified scan upper or lower
limit.
• For computation channels,
the FX sets the data to the
specified span upper or lower
limit.
p4 Data when the MAX, MIN, or P-P value
overflows
OVER
Uses the data that overflowed to
perform computations
SKIP
Discards the data that overflowed
and continues the computation
Description On models with the /M1, /PM1, or /PWR1 math
option, you can set p1 to MATH.
Report settings
Syntax
WU p1,p2,p3,p4,p5,p6
p1 Setting type (REPORT)
p2 Report computation type 1
MAX
Maximum value
MIN
Minimum value
AVE
Average value
SUM
Integrated value
INST
Instantaneous value
p3 Report computation type 2
OFF
Disables report computation
MAX
Maximum value
MIN
Minimum value
AVE
Average value
SUM
Integrated value
INST
Instantaneous value
p4 Report computation type 3
The same as p3
p5 Report computation type 4
The same as p3
p6 How to create the “hourly+daily,”
“daily+weekly,” and “daily+monthly” files
COMBINE Saves reports to one file
SEPARATE Saves reports to separate files
Description • On models with the /M1, /PM1, or /PWR1
math option, you can set p1 to REPORT.
• For parameters p2 to p5, you cannot specify
the same computation type. The exception
is OFF, which can be specified for multiple
parameters. However, you cannot set all these
parameters to OFF.
Service ports
Syntax
WU p1,p2,p3,p4,p5
p1 Setting type (SERVICEPORT)
p2 FTP service port (1 to 65535)
p3 Web service port (1 to 65535)
p4 SNTP service port (1 to 65535)
p5 Modbus service port (1 to 65535)
Description On models that have the Ethernet interface (/C7
option), you can set p1 to SERVICEPORT.
Decimal point type
Syntax
WU p1,p2
p1 Setting type (DECIMALPOINT)
p2 Decimal point type (POINT, COMMA)
POINT A period is used for the decimal
point.
COMMA A comma is used for the decimal
point.