Chapter 3 commands, 1 command syntax, 1 command syntax -1 – Yokogawa Value Series FX1000 User Manual
Page 83: App index, Command syntax
3-1
IM 04L21B01-17EN
Commands
1
2
3
4
5
6
App
Index
3.1 Command Syntax
Command Syntax
The syntax of the FX’s setting, basic setting, and output commands (see sections 3.4
to 3.9) is given below. ASCII (see appendix 3) is the supported character code. For the
syntax of the maintenance/test commands (see section 3.11) and instrument information
output commands (see section 3.12), see the corresponding sections or the examples for
each command.
Command name
Parameter
?
Terminator
Delimiter
Sub delimiter
SR002,SKIP;SR003,VOLT,2V,-1500,1800
Parameter
Delimiter (
,)
Command name (
SR)
Sub delimiter (
;)
Command example
Command Name
A command name is defined using two alphabet characters.
Parameters
• These are the command arguments.
• These are set using alphabet characters or numeric values.
• Parameters are separated by delimiters (commas).
• All numeric values are specified using integers.
• The valid ranges of numeric parameters vary depending on the command.
• Spaces around parameters are ignored. However, spaces are valid for parameters—
for example, units—that are specified using ASCII character strings. In the examples
given in this manual, spaces are not used.
• You can omit the parameters that do not need to be changed from their current
settings. However, delimiters cannot be omitted.
Example SR001,,2V
• If multiple parameters are omitted and there are multiple delimiters at the end of the
command, those delimiters can be omitted.
Example SR001,VOLT,,,
• For the following parameters, the number of digits or characters is fixed. If a value is
entered with the incorrect number of digits, a syntax error will occur.
• Date
YY/MM/DD (8 characters)
YY: Enter the last two digits of the year.
MM: Month
DD: Day
• Time
HH:MM:SS(8 characters)
HH: Hour
MM: Minute
SS: Second
• Channel number: 3 characters
• Relay number: 3 characters
Chapter 3
Commands