Styp, Stpt, Hour – Watlow Series 982 User Manual
Page 96: Rate, Ent3, Program menu
![background image](/manuals/359246/96/background.png)
7.2
WATLOW Series 982 User’s Manual
Programming, Chapter 7
Program Menu
[StYP]
Step Type:
Choose from five different step types. When selecting Step
1, you will not see the jump-loop (JL) or link file (LFiL) step type.
Range:
StPt, SoAh, JL, LFiL or End
Default:
End
[StPt]
Set Point Step (StPt) : The following parameters are associated
with the set point step.
[``SP]
Set Point
: The temperature the system tries to achieve for this step. This
is done linearly, producing a ramp from a beginning set point to this end
set point.
Range:
rL1 to rH1
Default:
75°F/24°C or rL value if rL
≥75°F/24°C or if rH≤75°F/24°C
[Hour]
Hour:
The number of hours, plus the Min and SEC parameters equal the
total step time to achieve the temperature under the StPt step type.
Range:
0 to 99
Default:
0
Hidden if: PtYP = rAtE
[Min]
Minutes:
The number of minutes plus the Hour and SEC parameters
equal the total step time to achieve the temperature under the StPt step
type.
Range:
0 to 59
Default:
0
Hidden if: PtYP = rAtE
[`SEC]
Seconds:
The number of seconds plus the Hour and Min parameters
equal the total step time to achieve the temperature under the StPt step
type.
Range:
0 to 59
Default:
0
Hidden if: PtYP = rAtE
[rAte]
Rate:
Represents the rate at which the set point changes in degrees per
minute. Decimal point location dependent on dEC1 (decimal 1) prompt.
Range:
0.0 to 360.0°F/0.0 to 200.0°C or 0.0 to 360.0 units
Default:
0.0
Hidden if: PtYP = ti
[Ent3]
Event 3:
Selects whether Event 3 is on or off.
Range:
On or OFF
Default:
OFF
Hidden if: Hardware not present or Ot3 = AL3, AL3n or no
NOTE:
Decimal points may
not always be in the
position specified
depending on the
value of Decimal 1
in the Input Menu.