beautypg.com

Model number, Ordering information – Watlow Series 982 User Manual

Page 139

background image

Appendix

WATLOW Series 982 User’s Manual

A.9

Model Number

1

Electromechanical relays warranted for 100,000 closures only. Solid-state switching
devices recommended for applications requiring fast cycle times or extended service life.

2

Not an ANSI symbol.

UL

®

is a registered trademark of the Underwriters Laboratories, Inc.

Slo-Blo

®

is a registered trademark of Littelfuse, Inc.

Series 981/982

9 8 _ C - _ _ _ _ - _ _ _ _

Power Supply & Mounting
1

=

100 to 240Vı (ac/dc) nominal, horizontal mounting

2

=

100 to 240Vı (ac/dc) nominal, vertical mounting

3

=

24 to 28Vı (ac/dc) nominal, horizontal mounting

4

=

24 to 28Vı (ac/dc) nominal, vertical mounting

Software
C

=

Standard (4-file, 6 step per file, program capability)

Input 1
1

=

Basic thermocouple signal conditioner (excluding Type B, R, and S)

2

=

Universal signal conditioner (see input range information)

Input 2
0

=

None

3

=

Slidewire feedback (see range information)

5

=

Second digital event (one digital event is standard on all units)

Output 1
B

=

Solid-state relay, Form A, 0.5A, with RC suppression

C

=

Switched dc or open collector, isolated

D

=

Electromechanical relay

1

, Form C, 5A with RC suppression

E

=

Electromechanical relay

1

, Form C, 5A without contact suppression

F

=

Universal process, 0-5VÎ (dc), 1-5VÎ (dc), 0-10VÎ (dc),
0-20mAÎ (dc), 4-20mAÎ (dc), isolated

K

=

Solid-state relay, Form A, 0.5A, without contact suppression

Output 2
A

=

None

B

=

Solid-state relay, Form A, 0.5A, with RC suppression

C

=

Switched dc or open collector, isolated

D

=

Electromechanical relay

1

, Form C, 5A with RC suppression

E

=

Electromechanical relay

1

, Form C, 5A without contact suppression

F

=

Universal process 0-5VÎ (dc), 1-5VÎ (dc), 0-10VÎ (dc),
0-20mAÎ (dc), 4-20mAÎ (dc), isolated

K

=

Solid-state relay, Form A, 0.5A, without contact suppression

T

=

External signal conditioner power supply, 5, 12 or 20VÎ (dc) @ 30mA

Output 3
A

=

None

B

=

Solid-state relay, Form A, 0.5A, with RC suppression

C

=

Switched dc, isolated

J

=

Electromechanical relay

1

, Form A or B, 5A without contact suppression

K

=

Solid-state relay, Form A, 0.5A without contact suppression

M

=

Retransmit, 0-20mAÎ (dc), 4-20mAÎ (dc)

N

=

Retransmit, 0-5VÎ (dc), 1-5VÎ (dc), 0-10VÎ (dc)

T

=

External signal conditioner power supply, 5, 12 or 20VÎ (dc) @ 30mA

Output 4
A

=

None

B

=

Solid-state relay, Form A, 0.5A, with RC suppression

C

=

Switched dc or open collector, isolated

D

=

Electromechanical relay

1

, Form C, 5A with RC suppression

E

=

Electromechanical relay

1

, Form C, 5A without contact suppression

K

=

Solid-state relay, Form A, 0.5A without contact suppression

R

=

EIA/TIA-232 communications, opto-isolated

S

=

EIA/TIA-485, EIA/TIA-422 communications, opto-isolated

T

=

External signal conditioner power supply, 5, 12 or 20VÎ (dc) @ 30mA

U

=

EIA/TIA-232 or EIA/TIA 485, opto-isolated

Display Color (Upper/Lower)
GG =

Green/Green

RG

=

Red/Green

GR =

Green/Red

RR

=

Red/Red

Ordering Information

(1080)

To order, complete the code number with the information below:

NOTE: User documentation may be available in French, German, Spanish,
Italian and Dutch, as well as English. Check Watlow’s website
(www.watlow.com/) for availability. Specify language at time of order.

This manual is related to the following products: