Event input 2, Abort set point, Ei2] [absp – Watlow Series 982 User Manual
Page 57: Setup-global
WATLOW Series 982 User’s Manual
4.31
Setup Menus, Chapter 4
Setup-Global
Event Input 2
Select the effect of closing the event input 2 switch.
• [``no] disables event input 2.
• [`LOC] locks out the front panel keys.
• [`ALr] resets an alarm.
• [`OFF] turns all control outputs off (de-energize relays, but does not hold
program).
• [[hold]] puts the controller into hold mode (ends the program and holds the
last set point).
• [FiL1] [FiL2] [FiL3] or [FiL4] starts file 1, 2, 3 or 4.
• [AbSP] controls to the abort set point.
• [PAuS] pauses a running profile.
• [`WE] can be configured as a waitfor event input.
[`Ei2] This prompt appears only on controllers with event input 2 hardware
(98__-_5__-____) and with [`In2] (Input Menu) set to [`Ei2].
Default
↓
[``no] [`LOC] [`ALr] [`OFF] [Hold] [FIL1] … [FIL4] [AbSP] [PAuS] [`WE]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
[`Ei2]
Abort Set Point
Select the set point that will take effect when a running profile is abort-
ed with an event input switch.
[AbSP] This prompt appears only on controllers with [`Ei1] or [`Ei2] set to
[AbSP].
Default
↓
[`OFF]
value of
…
value of
[AbSP]
[`rL1]
[`rH1]
(Input Menu) (Input Menu)
[`Ei2]
[AbSP]