beautypg.com

Sample program, Running your profile – Watlow Series 982 User Manual

Page 103

background image

WATLOW Series 982 User’s Manual

7.9

Programming, Chapter 7

the upper display. Press the Mode key to enter the Program menu.

2. The Series 981/982 asks you for a FiLE. The upper display reads 1.

Press the Mode key to select file 1.

3. The Series 981/982 asks you for a StEP. The upper display reads 1.

4. Press the Mode key to select step 1 and you are asked for a step type

(StyP). The default is End. Use the Up or Down key to select StPt (set
point).

5. Use Table 7.9 to enter the corresponding parameters and values. The

parameters appear from left to right on the table. Remember that the
Mode key is used to progress through the menu, and the Up and Down
keys are used to select parameters and values.

NOTE:

If auxiliary outputs are not present or Ot3 and Ot4 are selected

as alarms, the Ent3 and Ent4 parameters will not appear in the program

menu. If Event Input 1 or 2 is not selected as a waitfor event, the WE

parameter will not appear in the program menu.

Running Your Profile

Sample Program

Table 7.9 -
Sample Program.

150

125

100

75

50

0

0 5 10 15 20 25 30 35 40 45 50

Time

(seconds)

Temperature

(

°F)

Step 1:

initializes

set point

at 75

°F

Step 2:

ramps from

75

° to 100°F

Step 4:

an end step,

set point to off

Step 3:

a soak step,

holds set point

at 100

°F

Figure 7.9 -
Ramp and Soak
Profile.

Step #

StyP

Set Point

Hour

Min

SEC

Ent3

Ent4

WE

WPr

End

(Step Type)

1

StPt

75

0

0

1

OFF

OFF

--

--

--

2

StPt

100

0

0

25

On

OFF

--

--

--

3

SOAH

--

0

0

25

ON

OFF

dSbl

dSbL

--

4

End

--

--

--

--

--

--

--

--

OFF

This manual is related to the following products: