Linking Profiles

The Series 981/982 enables you to link files together. The Link step
allows you to link any step other than the first step of a profile to the first
step of another profile.

Let’s edit the profile again by adding a Link step to the end of File 1 in
place of the Jump-loop step. But first lets create another profile by pro-
gramming profile 2. Follow Table 7.12 to add a Link step to File 1 to link
it to File 2.

Run your program again beginning with File 1. Step through the
Run menu by using the Mode key. See what happens at the end of
File 1.

7.12

WATLOW Series 982 User’s Manual

Programming, Chapter 7

175

150

125

100

75

0

0

10

20

30

40

50

60

70

80

90

100 110

125

Time

(seconds)

Temperature

(

°F)

File 1,Step 5:

soak step

at 125

°F

File 2, Step 1:

ramps from

125

° to 175°F

Step 3:

ramps from

175

° to 100°F

Step 2:

a soak step,

holds set point

at 175

°F

Step 4:

a soak step,

holds set point

at 100

°F

Step 5:

ramps from

100

°F to 75°F

Step 6:

end program

and hold set point

Figure 7.12 -
Linking Profiles.

Sample Program

Table 7.12 -
Linking Profiles.

File #

Step #

StyP

Set

Hour

Min

SEC

Ent3

Ent4

WE

WPr

LFIL

End

(Step Type)

Point

1

6

LFiL

2

2

1

StPt

175

0

0

25

On

On

2

2

SoAH

0

0

25

On

On

dSbL

2

3

StPt

100

0

0

25

On

OFF

2

4

SoAH

0

0

25

On

OFF

dSbL

2

5

StPt

75

0

0

25

OFF

OFF

2

6

End

Hold