Menu overview, 2 menu overview, Operation menus display loop – Watlow Series 982 User Manual
Page 6: Setup menus factory menus
Factory Fcty ( )
1.2
WATLOW Series 982 User’s Manual
Starting Out with the Watlow Series 982, Chapter 1
Menu Overview
˜
NOTE:
This is a complete
listing of all Series
982 prompts.
Not all prompts will
appear on your
control. They are
dependent on your
configuration and
model number.
Figure 1.2 -
The Series 982 Map.
75
50
°F
0
% OUT LED on
DEV LED on
Process units
Set point 1
Pr2
Process input 2
(SyS)
Alarm 2 low
Alarm 2 high
Alarm 3 low
Alarm 3 high
(System)
Event input 1 status
Ei1S
A2LO
A2HI
A3LO
A3HI
A4LO
AUt
A4HI
( )
( )
( )
( )
( )
( )
( )
( )
Auto-tune
Alarm 4 high
Alarm 4 low
( )
( )
( )
Event input 2 status
Ei2S
Event output 3 status
Ent3
Event output 4 status
Ent4
(Pid)
Output 1 integral
Output 1 reset
Output 1 rate
Output 1 derivative
Output 1 cycle time
(PID)
Output 1 proportional band
Pb1
It1
rA1
dE1
Ct1
rE1
Pb2
It2
rA2
rE2
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
Output 2 integral
Output 2 reset
Output 2 rate
Output 2 proportional band
Ct2
db
dE2
( )
( )
( )
Output 2 cycle time
Output 2 derivative
Dead band
(Prog)
(Program)
( )
( )
( )
File number
Step number
Step type
FiLE
StEP
StyP
Test output
(diAg)
Software revision
Serial number
Ambient temperature
Ambient A/D count
(Diagnostics)
Factory ship date
dAtE
SOFt
Sn
AMb
Acnt
gnd
ity1
cnt1
Oty1
Oty2
Oty4
dISP
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
Input 1 A/D count
Input 1 module
Ground A/D count
Output 1 module
Output 2 module
Output 4 module
Test displays
tout
Oty3
( )
( )
Output 3 module
ity2
Input 2 module
cnt2
Input 2 A/D count
( )
(CAL)
(Calibration)
A 50
tc
A 4H
A 20
A 15
A 00
A380
A 0u
A20A
A10u
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
1 4
1 20
1 0
1 10
2 4
A 4A
Default prompts
2 20
2 0
2 10
3 LO
3 HI
rSt
dFL
A 0u
A100
( )
( )
Restore factory values
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
bu15
b380
( )
( )
Operation Menus
Display Loop
(Lower Display)
Setup Menus
Factory Menus
To navigate:
Press ∂ to return
to the Display Loop
from any location and
to advance through
the Display Loop.
Press > or < to
move between the
menus.
Press µ to
advance through a
menu.
Hold µ while
pressing > to move
backwards through
the menus.
Press > or < to
select prompt values.
At the SEt prompt,
press > and <
another 3 seconds to
enter the Factory
menus.
From the Display
Loop, press µ to
advance to the
OPEr prompt.
Press ∂ to exit any
menu and reach the
Display Loop at any
time.
Operation
OPEr ( )
(Input)
Decimal place 1
Range low 1
Range high 1
Calibration offset 1
Rtd calibration curve 1
Input 1 software filter
Input 2
In1 ( )
dEC1 ( )
rL1 ( )
rH1 ( )
CAL1 ( )
rtd1 ( )
Ftr1 ( )
In2 ( )
(InPt)
Output 1
Process 1
Hysteresis 1
Output 2
Process 2
Hysteresis 2
Alarm 2
Latching for alarm 2
Ot1 ( )
Prc1 ( )
HyS1 ( )
Ot2 ( )
Prc2 ( )
HyS2 ( )
AL2 ( )
LAt2 ( )
C_F ( )
Err ( )
Ei1 ( )
Ei2 ( )
Anun ( )
LoP ( )
AtSP ( )
gSd ( )
( Communication)
Baud rate
Data bit and parity
Protocol type
Address
Interface type
bAUd ( )
dAtA ( )
Prot ( )
Addr ( )
intF ( )
rL2 ( )
rH2 ( )
LmL ( )
LmH ( )
CAL2 ( )
Hunt ( )
Input 1
Range low 2
Learn high
Calibration offset 2
Hunt
Range high 2
Learn low
(OtPt)
SIL2 ( )
Ot3 ( )
AL3 ( )
HyS3 ( )
LAt3 ( )
SIL3 ( )
Ot4 ( )
AL4 ( )
HyS4 ( )
LAt4 ( )
SIL4 ( )
Aout ( )
Prc3 ( )
ArL ( )
Arh ( )
ACAL ( )
(Output)
Output 3
Alarm 3
Hysteresis 3
Latching for alarm 3
Silence alarm 3
Output 4
Alarm 4
Hysteresis 4
Silence alarm 2
Latching for alarm 4
Silence alarm 4
Analog output
Process 3
Retransmit low limit
Retransmit high limit
Retransmit calibration offset
(gLbL)
Celcius_Fahrenheit
Event input 2
Annunciator
Low power limit
High power limit
Auto-tune set point
Program type
Guaranteed soak deviation
(Global)
Idle set point
Profile start
Power outage
Pout ( )
IdSP ( )
PStr ( )
LOC ( ) Lockout
PtyP ( )
HiP ( )
Event input 1
Error Latching
(COM)
SEt ( )
AbSP ( ) Abort Set Point
SHyS ( )
Slidewire hysteresis
> <
From the Display
Loop, press > and
< for 3 seconds to
enter the Setup
menus.
> <
Setup
> <
.
.
.
(See Chapter 7
for all the