Program type, Guaranteed soak deviation, Ptyp – Watlow Series 982 User Manual
Page 60: Setup-global
4.34
WATLOW Series 982 User’s Manual
Setup Menus, Chapter 4
Program Type
Select whether the program type will be time based or ramp rate.
• [``ti] selects a time based program.
• [rAtE] selects a program type of ramp rate in degrees or units per
minute.
[PtyP] This prompt always appears.
Default
↓
[``ti]
[rAtE]
[PtyP]
[PtyP]
Guaranteed Soak Deviation
Guarantees that the process temperature or units is maintained with-
in the selected window centered on the set point. If the process tem-
perature or units varies above or below the set point by more than the
selected value, the time clock stops and the lower display alternately flash-
es [`gSd] and the current parameter until the process variable is again
within the window. Setting [`gSd] to [```0] disables guaranteed soak
deviation.
[`gSd] This prompt always appears.
If
Default
↓
↓
[``°F]
[```0] … [`999]
[`C_F]
[`gSd]
[`gSd]
(Global Menu)
[``°C]
[[```0] … [``55]
[`C_F]
[`gSd]
[`gSd]
(Global Menu)
[```0] … [`999]
units
a process input
[`gSd]
[`gSd]
is selected
[`gSd]
Setup-Global
[PtyP]