beautypg.com

Teledyne LeCroy ArbStudio User Manual

Page 46

background image

ArbStudio

38

922244-00 Rev A

This waveform is generated in a continuous mode until a new Force Trigger
command is applied.

This Force Trigger command activates the generation of subsequent
waveforms (the generation of the latter waveform starts only when
all points of the previous one are generated).

A Force Trigger command applied during the generation of the last
waveform activates the generation of the first waveform.

The generation can be interrupted at any time by a Force Stop
command.

In this mode the repetition number associated to any waveform is
ignored (the generation of one waveform starts only when all points
of the previous one have been generated).

PLEASE NOTE THE FOLLOWING:

If a unique waveform is inserted in the Generation Sequence, the
Single, Continuous and Burst modes are equivalent.

The Stop command resets the generation sequence and sets the
output voltage at 0V. A Start command applied after a Stop
command activates always the generation of the first waveform in
the Generation Sequence.

In Burst mode the graph and the duration column of the modulation
table are disabled, having no meanings.