10 configuration validity, 7 saving recording options – Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual
Page 285

USB Protocol Suite User Manual
Chapter 10: Recording Options
LeCroy Corporation
271
10.6.10 Configuration Validity
The USB Protocol Suite Software monitors the current trigger and filter configuration to
ascertain whether or not it is valid. The configuration may not be valid because of any of
the following reasons:
•
More resources are configured than exist in the hardware.
•
Conflicts occur between shared hardware resources.
•
Configurations may be incomplete, such as choosing an event like “SCSI
Command” but not selecting a specific command.
If Config is not valid (red), you must fix the problem, so that the green Config is Valid
shows in the status area. If this is not done, the configuration will not be applied to the
current Recording Rules, and the trigger or filter will not function.
10.7 Saving Recording Options
To complete your Recording Options settings, use the features at the bottom of the
Recording Options screen. These features remain the same no matter which of the
three Recording Options screens you are working in.
•
Click Save to save the currently specified Recording Options for use in future
recording sessions. Any file name can be specified, though use of the .rec is
recommended; if no extension is specified, .rec is added by default.
•
Click Load to load a previously saved *.rec file, thus restoring a previous set
of Recording Options.
•
The Save as Default function is equivalent to the Save function, specifying
the file name default.rec. Whenever you start up the Analyzer, it
automatically loads the default.rec file if one exists.
•
Click OK to apply any changes and close this dialog box.
•
Click Cancel to cancel any immediate changes you have made and exit the
Recording Options menu.