Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual
Lecroy usb protocol suite™ user manual
This manual is related to the following products:
Table of contents
Document Outline
- USB Protocol Suite User Manual
- Copyright
- Table of Contents
- Chapter 1: Overview
- 1.1 Common Features
- 1.1.1 Graphical Bus Traffic Display
- 1.1.2 Accurate Time Measurement (Voyager, Advisor T3)
- 1.1.3 CrossSync Control Panel (Voyager, Advisor T3)
- 1.1.4 Comprehensive Error Detection and Analysis
- 1.1.5 Real-Time Event Triggering and Capture Filtering
- 1.1.6 Advanced Event Counting and Sequencing
- 1.1.7 BusEngine Technology
- 1.2 Voyager M3 Analyzer
- 1.3 USBTracer/Trainer
- 1.4 Advisor
- 1.5 Advisor T3
- 1.6 USBMobile T2
- 1.7 USBMobile HS
- 1.1 Common Features
- Chapter 2: General Description
- 2.1 Voyager M3 System Components/Packing List
- 2.2 Voyager M3 PC Requirements
- 2.3 Voyager M3 Analyzer
- 2.4 Voyager M3 Specifications
- 2.5 USBTracer/Trainer System Components
- 2.6 USBTracer/Trainer Analyzer PC Requirements
- 2.7 The Installed USBTracer Unit
- 2.8 USBTracer System Setup
- 2.9 USBTracer/Trainer Specifications
- 2.10 USBTracer/Trainer External Interface Breakout Board
- 2.11 Advisor
- 2.12 Advisor PC Requirements
- 2.13 Advisor System Components/Packing List
- 2.14 Advisor Stand-Alone Unit
- 2.15 Advisor System Setup
- 2.16 Advisor Specifications
- 2.17 Advisor External Interface Breakout Board
- 2.18 Advisor T3
- 2.19 USBMobile T2 and USBMobile HS
- Chapter 3: Installation
- Chapter 4: Software Overview
- 4.1 Starting the Program
- 4.2 The Main Display Window
- 4.3 Tool Bar
- 4.3.1 Files, Searches, and Options
- 4.3.2 Zoom and Wrap
- 4.3.3 Miscellaneous
- 4.3.4 Analysis (Reports)
- 4.3.5 Recording
- 4.3.6 Generator (Traffic Generation for USB 3)
- 4.3.7 Generator (Traffic Generation for USB 2)
- 4.3.8 View Level
- 4.3.9 Trace Views
- 4.3.10 USB 2 USB 3 Show
- 4.3.11 USB 2.0 Display/Hide
- 4.3.12 USB 3.0 Display/Hide
- 4.4 Tooltips
- 4.5 View Options
- 4.6 Status Bar
- 4.7 Navigation Tools
- 4.8 CrossSync Control Panel
- 4.9 Analyzer Keyboard Shortcuts
- Chapter 5: Reading a Trace
- 5.1 Trace View Features
- 5.2 Set Marker
- 5.3 Edit or Clear Marker
- 5.4 Set or Clear Quick Timing Markers
- 5.5 Time Stamp
- 5.6 View Raw Bits (2.0)
- 5.7 Expanding and Collapsing Data Fields
- 5.8 Format/Color/Hide Fields
- 5.9 View Data Block
- 5.10 Pop-up Tool-tips
- 5.11 Hide SOF Packets (2.0)
- 5.12 Hide NAKs
- 5.13 Hide Devices
- 5.14 Hide Chirps (2.0)
- 5.15 Hide Link Commands (Flow Control) (3.0)
- 5.16 Hide ISO Time Stamp Packet (3.0)
- 5.17 Hide Link Training Sequences (3.0)
- 5.18 Hide Inter-Packet Symbols (3.0)
- 5.19 Hide Logical Idle Packets (3.0)
- 5.20 Hide Link Commands (non Flow Control) (3.0)
- 5.21 Hide Upstream Packets (3.0)
- 5.22 Hide LMP Packets (3.0)
- 5.23 Hide Downstream Packets (3.0)
- 5.24 Hide Electrical Idles (3.0)
- 5.25 Hide Skip Sequences (3.0)
- 5.26 Hide LFPS Packets (3.0)
- 5.27 Display 2 Only
- 5.28 Display 3 Only
- 5.29 Switch to Transactions View
- 5.30 View Decoded Transactions
- 5.31 Switch to Split Transaction View
- 5.32 Switch to Transfer View
- 5.33 View Decoded Transfers
- 5.34 Decoding Protocol-Specific Fields in Transactions and Transfers
- 5.35 Switch to Host Wire Adapter Segment View
- 5.36 Switch to Host Wire Adapter Transfer View
- 5.37 Switch to Device Wire Adapter Segment View
- 5.38 Switch to Device Wire Adapter Transfer View
- 5.39 Switch to PTP Transactions
- 5.40 Switch to PTP Object Transfers
- 5.41 Switch to PTP Sessions
- 5.42 Switch to SCSI Operations
- 5.43 Compressed CATC Trace View
- 5.44 Spreadsheet View
- 5.45 Edit Comment
- Chapter 6: Searching Traces
- Chapter 7: Display Options
- Chapter 8: Decode Requests
- 8.1 Class and Vendor Definition Files
- 8.2 Class/Vendor Decoding Options
- 8.2.1 Mapping Request Recipient to Class/Vendor Decoding
- 8.2.2 Mapping Endpoint to Class/Vendor Decoding
- 8.2.3 Mapping Request RPipe to Class/Vendor Decoding
- 8.2.4 Mapping Endpoint RPipe to Class/Vendor Decoding
- 8.2.5 Mapping Request DWA RPipe to Class/Vendor Decoding
- 8.2.6 Mapping Endpoint DWA RPipes to Class/Vendor Decoding
- 8.3 General Options
- Chapter 9: Reports
- 9.1 File Information
- 9.2 Error Summary
- 9.3 Timing Calculations
- 9.4 Data View
- 9.5 Traffic Summary
- 9.6 Bus Utilization
- 9.7 Link Tracker (3.0)
- 9.8 Using the Trace Navigator
- 9.9 Detail View
- 9.10 Spec View (3.0)
- 9.11 USB3 Link State Timing View
- 9.12 USB3 LTSSM View
- 9.13 Power Tracker
- 9.14 Running Verification Scripts
- 9.15 Real Time Monitoring
- Chapter 10: Recording Options
- 10.1 General Recording Options
- 10.2 Recording Options - Misc. USB 2.0 (Voyager, Advisor T3, USBTracer/Trainer, and Mobile)
- 10.3 Recording Options - Misc. USB 3.0 for Voyager
- 10.4 Recording Options - Misc. USB 3.0 for Advisor T3
- 10.5 Recording Rules - USB 2.0
- 10.5.1 Recording Rules Toolbar
- 10.5.2 Recording Rules Page: How It Works
- 10.5.3 Creating Event Buttons
- 10.5.4 Dragging a Button to the Main Display Area
- 10.5.5 Assigning an Action
- 10.5.6 Recording Rules Pop-Up Menus
- 10.5.7 Events and Event Properties for USB 2.0
- 10.5.8 Counters and Timers for USB 2.0
- 10.5.9 Actions and Action Properties
- 10.5.10 Using a Single-State Sequence
- 10.5.11 Using a Multi-State Sequences
- 10.5.12 Using Independent Sequences
- 10.6 Recording Rules - USB 3.0 (Voyager only)
- 10.6.1 Recording Rules Toolbar
- 10.6.2 Recording Rules Page: How It Works
- 10.6.3 Creating Event Buttons
- 10.6.4 Dragging a Button to the Main Display Area
- 10.6.5 Assigning an Action
- 10.6.6 Recording Rules Pop-Up Menus
- 10.6.7 Actions and Action Properties
- 10.6.8 Events and Event Properties for USB 3.0
- 10.6.9 Counters and Timers for USB 3.0
- 10.6.10 Configuration Validity
- 10.7 Saving Recording Options
- 10.8 Recording Bus Data
- 10.9 Merging Trace Files
- 10.10 Recording Option Summary Tab
- Chapter 11: Traffic Generation (2.0)
- 11.1 Connecting to the Exerciser/Generator
- 11.2 Traffic Generation Files
- 11.3 Creating Traffic Generation Files
- 11.4 Editing a Generation File
- 11.5 Loading the Generation File
- 11.6 Starting Traffic Generation
- 11.7 Repeating a Generation Session
- 11.8 Stop Traffic Generation
- 11.9 Device Emulation
- 11.10 Format of Traffic Generation Files
- Chapter 12: Traffic Generation (3.0 Exerciser)
- 12.1 Connecting to Voyager
- 12.2 Transaction Engine
- 12.3 Exerciser Files
- 12.4 Creating Exerciser Files
- 12.5 Exerciser Window
- 12.6 Script Editor
- 12.7 Creating a Script using the Script Editor
- 12.8 Graphical Scenario Editor
- 12.9 Loading and Running the Generation File
- 12.10 Exporting a Trace to a Traffic Generation File
- 12.11 USB 3.0 Electrical Test Modes
- Chapter 13: Updates
- Appendix A: China Restriction of Hazardous Substances Table
- How to Contact LeCroy
- Limited Hardware Warranty
- Index