USB Protocol Suite User Manual
Chapter 1: Overview
LeCroy Corporation
13
The Analyzer is a plug-in module that installs into a LeCroy Universal Protocol Analyzer 
System (UPAS). Together, the Analyzer and UPAS are controlled from a personal 
computer USB port across a USB connection. 
Figure 1.6
System Setup
USBTracer provides on-the-fly detection of, and triggering on, events such as Tokens and 
Errors. Whether recording manually or with a specified trigger condition, USBTracer 
continuously records the link data in a wrap-around fashion until manually stopped or until 
the system detects a Trigger Event and records the specified post-trigger amount of link 
data.
Upon detection of a triggering event, the Analyzer continues to record data up to a point 
specified by the user. You can individually enable or disable real-time detection of events 
to allow triggering on events as they happen, including predefined exception or error 
conditions and user-defined sets of trigger events. An externally supplied signal can 
trigger the Analyzer. An external DB-25 connector provides a path for externally supplied 
data or timing data to be recorded along with traffic.
The DB-25 connector also provides a path for USBTracer to transmit externally the 
software trigger signal or a user-defined event, for probing or use by other circuitry.
Search functions allow the software to identify and highlight specific events. In addition 
to immediate analysis, you can print any part of the data. You can save the data on disk 
for later viewing. You can generate timing information and data analysis reports.