2 mapping endpoint to class/vendor decoding – Teledyne LeCroy USBTracer_Trainer - Users Manual User Manual
Page 176

Chapter 8: Decode Requests
USB Protocol Suite User Manual
162
LeCroy Corporation
8.2.2 Mapping Endpoint to Class/Vendor Decoding
To assign a Class/Vendor Endpoint decoding,
Step 1 Click the Apply Decoding Scripts button on the Toolbar.
OR
Right-click the Bulk/Int Transfer field to display the USB Device Request menu.
Step 2 Select Map Endpoint to Class/Vendor Decoding to display the Request
Recipients and Endpoints dialog box.
Step 3 Click the Endpoints tab to display the Endpoints dialog box.
The Endpoint field (Endp) shows all Endpoints found in the trace file. The
displays shows the Host, Address, and Direction for the recipient. On the right
are the names of Class/Vendor Endpoint Decoding groups currently assigned to
endpoints. If blank, no decoding is assigned for a recipient.
Step 4 Select an endpoint.