10.2.1 Analyzer Speed
This option sets the speed of the traffic recorded by the Analyzer. The default setting is 
Auto-detect. This setting tells the Analyzer to discover what speed traffic is running and 
to label packets accordingly. If you are having problems with your recordings, you might 
try setting the traffic speed to one of the fixed values -- Low, Full, and Hi speed. These 
settings are used when you want to manually set the traffic speed. 
In some rare cases, auto-detection circuitry causes Full Speed devices to fail to 
enumerate on plug-in. Changing the Analyzer speed to Full Speed can sometimes solve 
this problem.
Setting the speed to one of the fixed values is sometimes useful for debugging purposes. 
For example, if a device that is producing numerous errors at a particular speed, you may 
wish to set the recording to that speed in order to ensure that the Analyzer does not 
misread the error packets and label them the wrong speed. While it is unlikely that the 
Analyzer will mislabel packets in this way, manually setting the recording speed 
guarantees that the Analyzer always records packets at the correct speed.
Notes on Hi Speed Recordings
Erroneous chirp blocks can be recorded on an idle bus when the Device has its FS 
terminations on while the Host has HS terminations connected. This causes a small 
differential voltage (“tiny-J”) on the USB bus that causes false Chirp detection. 
This condition occurs during speed negotiation:
•
On a HS bus, the condition is momentary just before the device chirps.
•
On a CS bus, the condition occurs both before and after the device chirp (until 
the end of Reset). The user is discouraged from using Speed=HIGH to record 
signals on a classic speed bus.
•
The Analyzer stops recording anything for 2.5 milliseconds following a FS_K 
state (which is at least 2 microseconds long). This is to avoid presenting 
“garbage” which is a by-product of the high-speed probe settling down.
10.2.2 Generator/Analyzer Clocking Overrides
Generator/Analyzer Clocking Overrides allows changes to be made to the 
Analyzer/generator clocking. Select Slow Clock, then enter a value in the box on the 
right. The value that is entered tells the Analyzer how much to divide the base clock by. 
For example, entering a 4 causes Full Speed traffic to be generated at a 3-megabit rate 
as opposed to the standard 12-megabit rate.
You can use the slow clock selection to slow down the base clock during generation. This 
also changes the Analyzer’s clock base to match.
Step 1 In the Misc. USB 2.0 tab, make sure you are out of Auto-Detect mode.
Step 2 Select the Slow Clock checkbox.
Step 3 In the Divide By field, enter a value.
Step 4 Click OK.