5. Operation of CON Related Controllers
79
5.13 User Adjustment
You can perform home return, etc.
Touch [User Adjust] on the Menu 2 screen.
If a system password is set, the password setting screen appears.
Input a system password.
The user adjustment screen appears.
Touch [Adjust No.] and the numeric key pad opens. Set [Adjust No.]
and touch [Execute.]
[Adjust No.]
x
1: Home return
Home return can be performed.
x
2: Axis number setting
The operation is the same as what you do on the axis number
setting screen.
x
3: Alarm list clear
The operation is the same as what you do on the alarm list
screen.
x
4: Controller restart
The operation is the same as what you do when restarting the
controller on the Menu 2 screen.
x
7: Time setting
You can move to the time setting screen to set time.
(SCON-CA, PCON-CA, ERC3 PIO Converter and MSCON)
x
8: Maintenance information
Maintenance information can be displayed.
(SCON-CA, PCON-CA, ERC3 PIO Converter and MSCON)
(Note) Adjustment numbers 7 and 8 can be set only on SCON-CA,
PCON-CA, ERC3 PIO Converter and MSCON.
The default password is "5119."
You can set a password on the setting screen.