6. Operation of SEP
Related Controllers
142
6.11 I/O Setting (Setting of Operation Parameters, Etc.)
You can select an operation pattern (PIO pattern) (0 to 5), set an operation mode (single solenoid, double
solenoid), etc.
Touch [Initial Set] on the SEP menu screen.
Touch [I/O set]
Touch [Menu] to return to the SEP menu screen.
The password entry screen appears before the initial setting screen.
Enter a password value from the numeric keypad, and then touch
[ENT].
If the correct password has been entered, the display changes to the screen for setting the operation
pattern.
Select and touch one of operation patterns [0] to [5], and then touch
[OK].
(Note) If connected to Fieldbus Type in MSEP Controllers, [6]
(Positioner Mode) is shown.
If selecting [6], it is not necessary to have an operation for the
initial setting.
The operation is complete.
The password is "5119" (default setting).