IAI America CON-PGA User Manual
Page 38
5. Operation of CON Related Controllers
30
MSCON
IO monitor screen
Touching [Mon Main] switches to the main monitor
display
Touching [Data Mon] changes the display to show
data such as the current position and control voltage.
Touching [Axis No.] switches the screen to one
where you can select an axis.
x
Input
The status of each input port is shown. ON is lit. OFF is unlit.
x
Output
The status of each output port is shown. ON is lit. OFF is unlit.
MSCON
Data monitor screen
Touching [Mon Main] switches to the main monitor
display
Touching [IO Mon] changes the display to one
showing only I/Os.
Touching [Axis No.] switches the screen to one
where you can select an axis.
Touch [Current] to display [Current Rate].
Touch [Current Rate] to display [Current].
x
Position
The current position is shown.
x
Velocity
The speed is shown.
x
Pulse count
The pulse count is shown. Touching [Pulse Count] displays the pulse count.
(The pulse count is shown in the pulse-train control mode.)
x
Current Rate
The command value of electrical current is shown as a percentage of the rated
current.
x
Current
The command value of electrical current is shown. Touch [Current Rate] to
display the command value.
x
Alarm Code
The applicable alarm code is shown.
x
Servo
The servo ON status is shown. ON is lit. OFF is unlit.
x
Home
The home return status is shown. Lit, if home return has completed.
x
PCBTemperature
The PCB temperature is shown.