5. Operation of CON Related Controllers
57
4) Jogging, Use [Jog+] or [Jog-] to jog the actuator to the target position, and then acquire the achieved
position (current position) into the position data table and specify that position.
Note that if the maximum speed is smaller than the specified speed, the speed is clamped at the
maximum speed.
To perform jog operation immediately after turning on the power, home return must be performed
first. (Refer to page 37.) (Incremental specification)
No.
Operation
Screen
Remarks
1 Touch [Edit Position].
2 If the password is not "0000,"
the password screen appears.
Input a password.
The default password is
"0000."
3 The position data table screen
appears.
4
Touch [n] and [p] to display the
table showing the position
number you want to set.
If data is already entered, the
current data is overwritten.
Position data fields in which no
data is registered yet contain an
"*" (asterisk).
5 Next, touch No. "000" of
position No. 0.
6 Touch [Jog].