6 initial setting – IAI America CON-PGA User Manual
Page 190

7. Operation of MEC Related Controllers
182
7.6 Initial Setting
Select whether to stop at 2 points or 3 points.
Touch [Initial Set] on the MEC menu screen.
Before the display switches to the initial setting screen, the password entry screen appears if the password
is other than “0000.”
Enter the password using the numeric keypad, and then touch
[ENT].
The password is “5119” (factory setting).
You can set a desired password using the “system password”
parameter accessible from the maintenance menu.
If the valid password has been set, the display switches to the initial setting screen.
Stopping at 2 points
Select and touch either [Two Point] or [Three Point]. To perform
positioning Operationelect and touch [Pushing None]. To perform
push-motion Operationelect and touch [Pushing].
To stop at 3 points, select [Both OFF] or [Both ON] as the
position specification method.
(Note) Take note that if push-motion operation is performed
and therefore [Pushing None] is selected, the
completion signal will not be output.
* If [Pushing None] is selected, LS0 and LS1 (LS2) will be used
as output signals. If [Pushing] is selected, PE0 and PE1 (PE2)
will be used as output signals.
Stopping at 3 points