5. Explanation of Operating Functions

52

(Controller o PLC)

Register

Bit

address

Bit

position

Signal

symbol

Signal name

Description

15

to

9

-

-

-

0147H

8

PZONE

Position zone

output

If individual zone boundaries are set in the

position table, this bit will turn “1” when the

current position enters the range specified

by the boundaries.

7

to

2

-

-

-

014EH

1

ZONE2

Zone output 2

This bit will turn “1” when the current

position enters the range specified by the

zone boundary 2 parameters.

Zone status

register

ZONS

Address

9013H

[Common]

014FH

0

ZONE1

Zone output 1

This bit will turn “1” when the current

position enters the range specified by the

zone boundary 1 parameters.

15

to

6

-

-

-

013AH

5

PM32

013BH

4

PM16

013CH

3

PM8

013DH

2

PM4

013EH

1

PM2

Position

number

status

register

POSS

Address

9014H

[POS

specification] 013FH

0

PM1

A completed position number is output

using a 6-bit binary code.

(Controller o PLC)

Register Address

Description

PNOW

Current

position

[Numerical

specification]

The current position is indicated by a signed 32-bit integer (unit: 0.01 mm).

A negative value is indicated by a 2’s complement. Accordingly, the most significant bit

becomes “1.”

Upper

Lower

Sign