(2) Wiring the cables

z

Use IAI’s genuine cables to connect the actuator and controller or connect a teaching

tool, etc.

z

Do not damage, forcibly bend, pull, loop round an object or pinch the cables or place

heavy articles on top. Current leak or poor electrical continuity may occur, resulting in

fire, electric shock or malfunction.

z

Wire the product correctly after turning off the power.

z

When wiring a DC power supply (+24 V), pay attention to the positive and negative

polarities.

Connecting the wires in wrong polarities may result in fire, product failure or

malfunction.

z

Securely connect the cables and connectors so that they will not be disconnected or

come loose. Failing to do so may result in fire, electric shock or product malfunction.

z

Do not cut and reconnect the cables of the product to extend or shorten the cables.

Doing so may result in fire or product malfunction.

(3) Grounding

z

Be sure to provide class D (former class 3) grounding for the controller. Grounding is

required to prevent electric shock and electrostatic charges, improve noise resistance

and suppress unnecessary electromagnetic radiation.

4 Installation/

startup

(4) Safety measures

z

Implement safety measures (such as installing safety fences, etc.) to prevent entry

into the movement range of the robot when the product is moving or can be moved.

Contacting the moving robot may result in death or serious injury.

z

Be sure to provide an emergency stop circuit so that the product can be stopped

immediately in case of emergency during operation.

z

Implement safety measures so that the product cannot be started only by turning on

the power. If the product starts suddenly, injury or product damage may result.

z

Implement safety measures so that the product will not start upon cancellation of an

emergency stop or recovery of power following a power outage. Failure to do so may

result in injury, equipment damage, etc.

z

Put up a sign saying “WORK IN PROGRESS. DO NOT TURN ON POWER,” etc.,

during installation, adjustment, etc. If the power is accidently turned on, electric shock

or injury may result.

z

Implement measures to prevent the work part, etc., from dropping due to a power

outage or emergency stop.

z

Ensure safety by wearing protective gloves, protective goggles and/or safety shoes,

as necessary.

z

Do not insert fingers and objects into openings in the product. Doing so may result in

injury, electric shock, product damage, fire, etc.

z

When releasing the brake of the vertically installed actuator, be careful not to let the

actuator drop due to its dead weight, causing pinched hands or damaged work part,

etc.

5 Teaching

z

Whenever possible, perform teaching from outside the safety fences. If teaching must

be performed inside the safety fences, prepare “work rules” and make sure the

operator understands the procedures thoroughly.

z

When working inside the safety fences, the operator should carry a handy emergency

stop switch so that the operation can be stopped any time when an abnormality

occurs.

z

When working inside the safety fences, appoint a safety watcher in addition to the

operator so that the operation can be stopped any time when an abnormality occurs.

The safety watcher must also make sure the switches are not operated inadvertently

by a third party.

z

Put up a sign saying “WORK IN PROGRESS” in a conspicuous location.

No.

Operation

Description

Description

6

Trial Operation Ɣ When the work is carried out with 2 or more persons, make it clear who is

to be the leader and who to be the follower(s) and communicate well with

each other to ensure the safety of the workers.

Ɣ After the teaching or programming operation, perform the check operation

one step by one step and then shift to the automatic operation.

Ɣ When the check operation is to be performed inside the safety protection

fence, perform the check operation using the previously specified work

procedure like the teaching operation.

Ɣ Make sure to perform the programmed operation check at the safety

speed. Failure to do so may result in an accident due to unexpected

motion caused by a program error, etc.

Ɣ Do not touch the terminal block or any of the various setting switches in

the power ON mode. Failure to do so may result in an electric shock or

malfunction.

7

Automatic

Operation

Ɣ Check before starting the automatic operation or rebooting after operation

stop that there is nobody in the safety protection fence.

Ɣ Before starting automatic operation, make sure that all peripheral

equipment is in an automatic-operation-ready state and there is no alarm

indication.

Ɣ Make sure to operate automatic operation start from outside of the safety

protection fence.

Ɣ In the case that there is any abnormal heating, smoke, offensive smell, or

abnormal noise in the product, immediately stop the machine and turn

OFF the power switch. Failure to do so may result in a fire or damage to

the product.

Ɣ When a power failure occurs, turn OFF the power switch. Failure to do so

may cause an injury or damage to the product, due to a sudden motion of

the product in the recovery operation from the power failure.