IAI America ERC2 User Manual
Page 112
0
7. T
roubleshooting
93
7.4 Messages Displayed during Operation Using the Teaching Pendant or PC
Software
This section explains the warning messages that may be displayed during operation using the teaching pendant
or PC software.
Code
Error name
Cause/Action
112 Invalid data
An inappropriate value was entered in a parameter.
(Example) 9601 was entered as the serial communication speed by
mistake.
Enter an appropriate value again.
113 Value too small
The entered value is smaller than the setting range.
114 Value too large
The entered value is larger than the setting range.
Refer to the actuator specifications or parameter table and enter an
appropriate value again.
115 Home return non-
completion
The current position was written when home return was not yet completed.
Execute home return again.
116 Last position data available Data was already set in the fields for the last position when an attempt was
made to add data to the position table. Clear or delete the data for the last
position before adding data.
117 No movement data
Target position is not set under the selected position number.
Enter the target position first.
11E Paired data mismatch
The values indicating the magnitude relationship of a pair of data are
inappropriate.
(Example) The same value was entered in both the parameters for + and –
soft limits.
Enter appropriate values again.
11F Absolute position too small The minimum movement toward the target position is determined by the
lead length of the drive system and resolution of the encoder.
This message indicates that the entered target value is smaller than the
minimum movement.
(Example) If the lead length is 16 mm, the encoder’s resolution is 800
pulses and accordingly the minimum movement becomes 16 y
800 = 0.02 mm/pulse.
In this case, this message will be displayed if 0.01 mm is entered
as the target position.
121 Push & hold search end
over
The final position in push & hold operation exceeds the soft limit.
This has no negative effect if the actuator contacts the work part. If the
actuator misses the work part, however, the soft limit will be reached and
thus this message is displayed as a warning.
Change either the target position or positioning band.
122 Multiple axes connected at
assignment
Address was assigned when multiple axes were connected.
Assign each address only when one axis is connected.
180
181
182
183
Address change OK
Controller initialization OK
Home change all clear
I/O function changed
These messages are displayed to confirm operation.
(They don’t indicate an operation error or other abnormality.)
202 Emergency stop
An emergency stop status was detected. (This is not an error.)