background image

4. W
iring

30

4. Wiring

4.1 Basic Configuration with SIO Converter

Connect a teaching pendant, PC or PLC using a SIO converter (for RS232C/RS485 conversion), as shown

below.

Caution: Do not connect any device to the mini-DIN connector and D-sub connector at the same

time. If a device is connected to these connectors at the same time, a communication

error (message level) will occur.

PC software

RS232C type

USB type

Optional

Teaching pendant

Optional

Cable length: 5 m

ERC2-SE actuator

RS232C crossed cable (generic brand)

*1 Connect the communication line from the actuator

to either TB1 or J4 (J5) on the SIO converter, as

shown below.

*2 The customer must produce an appropriate cable.

SIO converter

Vertical

Horizontal

e-CON

connector

Network connection

cable

J.S.T.

Mfg.

24-VDC control power, motor power,

brake signal, ground, shield

Power & I/O cable

J.S.T. Mfg.

(

Female)

(

Female)

(

Female)

Supplied cable

(Male)

(Male)