1. Overview

12

1.8 Installation Environment and Noise Elimination

Pay due attention to the installation environment of the controller.

1.8.1 Installation Environment

The installation environment must satisfy the following conditions:

No.

Use environment/condition

[1]

Not exposed to direct sunlight.

[2]

The actuator is not subject to irradiated heat from a large heat source, such as a heat treatment

furnace.

[3]

Ambient temperature of 0 to 40qC.

[4]

Humidity of 85% or less without condensation.

[5]

Not exposed to corrosive or flammable gases.

[6]

Normal environment for assembly and operation not subject to significant dust.

[7]

Not exposed to oil mist or cutting fluid.

[8]

Not subject to vibration exceeding 0.3 G.

[9]

Not exposed to strong electromagnetic waves, ultraviolet light or radiation.

[10] Chemical resistance is not considered at all in the design of this product.
[11] The actuator and cables are not subject to electrical noise.

In general, the installation environment shall be such that the operator can work without wearing any protective

gears.

1.8.2 Storage Environment

The storage environment shall conform to the installation environment, but special caution is required to prevent

condensation if the actuator is to be stored for a long period of time.

Unless otherwise specified, the actuator is shipped without any desiccating agent placed in the box. If the

actuator is to be stored in an environment subject to condensation, provide a non-condensing measure from

outside the box or directly inside the box.

The actuator is designed to withstand storage temperatures of up to 60qC for a short period of time. If the

storage period will extend beyond one month, however, keep the storage temperature below 50qC.